Publication:
Corrugated stainless steels embedded in mortar for 9 years: corrosion results of non-carbonated, chloride-contaminated samples

dc.affiliation.dptoUC3M. Departamento de Ciencia e Ingeniería de Materiales e Ingeniería Químicaes
dc.affiliation.grupoinvUC3M. Grupo de Investigación: Comportamiento en Servicio de Materialeses
dc.contributor.authorBautista Arija, María Asunción
dc.contributor.authorParedes, E. C.
dc.contributor.authorVelasco López, Francisco Javier
dc.contributor.authorÁlvarez, S. M.
dc.date.accessioned2016-05-13T11:42:09Z
dc.date.issued2015-09-15
dc.description.abstractMortar samples reinforced with 5 different corrugated stainless steels were tested for 9 years in 2 different conditions: partial immersion (PI) in 3.5% NaCl, and chloride addition to the mortar and exposure to high relative humidity (HRH). The monitoring during the exposures was carried out with corrosion potential (E-corr) and electrochemical impedance spectroscopy (EIS) measurements. A year before finishing (after 8 years of exposure), the reinforced mortar samples were anodically polarised to obtain more information about the pitting resistance of the passive layers formed under the different conditions. The last year of exposure was established to study the progress or repassivation of the pits. The PI is the most aggressive testing condition and it causes low-intensity corrosion in S20430 austenitic stainless steel after 7 years of exposure. The S32205 duplex stainless steel shows very good corrosion behaviouren
dc.description.sponsorshipThe present work was funded by the Spanish Ministry of Science and Innovation through the Project reference BIA2007 66491 C02 02.en
dc.format.extent10es
dc.format.mimetypeapplication/pdf
dc.identifier.bibliographicCitationConstruction and building materials 93 (2015), pp. 350-359en
dc.identifier.doi10.1016/j.conbuildmat.2015.04.060
dc.identifier.issn0950-0618
dc.identifier.publicationfirstpage350es
dc.identifier.publicationlastpage359es
dc.identifier.publicationtitleConstruction and building materialsen
dc.identifier.publicationvolume93es
dc.identifier.urihttps://hdl.handle.net/10016/22970
dc.identifier.uxxiAR/0000017160
dc.language.isoengen
dc.publisherElsevier Ltd.es
dc.relation.ispartofhttp://hdl.handle.net/10016/22979
dc.relation.projectIDGobierno de España. BIA2007 66491 C02 02es
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.conbuildmat.2015.04.060es
dc.rights© 2015 Elsevier Ltd.es
dc.rightsAtribución–Nocomercial–Sinderivadas 3.0 España*
dc.rights.accessRightsopen accessen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.ecienciaMaterialeses
dc.subject.otherStainless steelen
dc.subject.otherSteel reinforced mortaren
dc.subject.otherEISen
dc.subject.otherPolarisationen
dc.subject.otherPassivityen
dc.subject.otherPitting corrosionen
dc.titleCorrugated stainless steels embedded in mortar for 9 years: corrosion results of non-carbonated, chloride-contaminated samplesen
dc.typeresearch article*
dc.type.hasVersionAM*
dspace.entity.typePublication
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
corrugated_CBM_2015_ps.pdf
Size:
2.05 MB
Format:
Adobe Portable Document Format