Publication: Reduction of respiratory blurring in small-animal CT scans based on a fast retrospective gating method
dc.affiliation.dpto | UC3M. Departamento de Bioingeniería | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: Biomedical Imaging and Instrumentation Group | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: BSEL - Laboratorio de Ciencia e Ingeniería Biomédica | es |
dc.contributor.author | Chavarrías, Cristina | |
dc.contributor.author | Vaquero López, Juan José | |
dc.contributor.author | Sisniega, Alejandro | |
dc.contributor.author | Rodríguez, A. | |
dc.contributor.author | Soto Montenegro, Mª Luisa | |
dc.contributor.author | Desco Menéndez, Manuel | |
dc.date.accessioned | 2011-08-18T11:53:14Z | |
dc.date.available | 2011-08-18T11:53:14Z | |
dc.date.issued | 2008-06 | |
dc.description | [Abstract] The 22nd International Congress and Exhibition, Barcelona, Spain, June 25-28, 2008 | |
dc.description.abstract | The purpose of the present work was to develop a fast retrospective method to extract the respiratory signal from the CT projections in cone beam geometry and to obtain dynamic breathing studies in small animal scans. The whole process had to be software-based and automatic, avoiding the use of any additional respiratory gating instruments | |
dc.description.status | Publicado | |
dc.format.mimetype | application/pdf | |
dc.identifier.bibliographicCitation | International Journal of Computer Assisted Radiology and Surgery, jun. 2008, vol. 3, supplement 1, p. S13-S14 | |
dc.identifier.doi | 10.1007/s11548-008-0166-0 | |
dc.identifier.issn | 1861-6410 (print version) | |
dc.identifier.issn | 1861-6429 (electronic version) | |
dc.identifier.publicationfirstpage | S13 | |
dc.identifier.publicationissue | supplement 1 | |
dc.identifier.publicationlastpage | S14 | |
dc.identifier.publicationtitle | International Journal of Computer Assisted Radiology and Surgery | |
dc.identifier.publicationvolume | 3 | |
dc.identifier.uri | https://hdl.handle.net/10016/12021 | |
dc.language.iso | eng | |
dc.publisher | Springer | |
dc.relation.eventdate | June 25-28, 2008 | |
dc.relation.eventnumber | 22 | |
dc.relation.eventplace | Barcelona, Spain | |
dc.relation.eventtitle | International Congress and Exhibition | |
dc.relation.publisherversion | http://dx.doi.org/10.1007/s11548-008-0166-0 | |
dc.rights | ©Springer | |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | |
dc.subject.eciencia | Biología y Biomedicina | |
dc.subject.other | 4D-CT | |
dc.subject.other | Retrospective gating | |
dc.subject.other | Respiratory signal extraction | |
dc.subject.other | Motion artifacts | |
dc.subject.other | Micro-CT | |
dc.title | Reduction of respiratory blurring in small-animal CT scans based on a fast retrospective gating method | |
dc.type | conference proceedings | * |
dc.type.hasVersion | AM | * |
dspace.entity.type | Publication |