Publication: Online condition monitoring of MV cable feeders using Rogowski coil sensors for PD measurements
dc.affiliation.dpto | UC3M. Departamento de IngenierĂa ElĂ©ctrica | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: Diagnóstico de Máquinas Eléctricas y Materiales Aislantes (DIAMAT) | es |
dc.contributor.author | Shafiq, Muhammad | |
dc.contributor.author | Kauhaniemi, K. | |
dc.contributor.author | Robles Muñoz, Guillermo | |
dc.contributor.author | Isa, M. | |
dc.contributor.author | Kumpulainen, L | |
dc.date.accessioned | 2023-07-17T08:05:34Z | |
dc.date.available | 2023-07-17T08:05:34Z | |
dc.date.issued | 2019-02-01 | |
dc.description.abstract | Condition monitoring is a highly effective prognostic tool for incipient insulation degradation to avoid sudden failures of electrical components and to keep the power network in operation. Improved operational performance of the sensors and effective measurement techniques could enable the development of a robust monitoring system. This paper addresses two main aspects of condition monitoring: an enhanced design of an induction sensor that has the capability of measuring partial discharge (PD) signals emerging simultaneously from medium voltage cables and transformers, and an integrated monitoring system that enables the monitoring of a wider part of the cable feeder. Having described the conventional practices along with the authors' own experiences and research on non-intrusive solutions, this paper proposes an optimum design of a Rogowski coil that can measure the PD signals from medium voltage cables, its accessories, and the distribution transformers. The proposed PD monitoring scheme is implemented using the directional sensitivity capability of Rogowski coils and a suitable sensor installation scheme that leads to the development of an integrated monitoring model for the components of a MV cable feeder. Furthermore, the paper presents forethought regarding huge amount of PD data from various sensors using a simplified and practical approach. In the perspective of today's changing grid, the presented idea of integrated monitoring practices provide a concept towards automated condition monitoring. | en |
dc.description.sponsorship | This work is done under the project Smart Condition Monitoring of Power Grid that is funded by the Academy of Finland (Grant No. 309412). | en |
dc.identifier.bibliographicCitation | Shafiq, M., Kauhaniemi, K., Robles, G., Isa, M., & Kumpulainen, L. (2019). Online condition monitoring of MV cable feeders using Rogowski coil sensors for PD measurements. Electric Power Systems Research, 167, pp. 150-162. | es |
dc.identifier.doi | 10.1016/j.epsr.2018.10.038 | |
dc.identifier.issn | 0378-7796 | |
dc.identifier.publicationfirstpage | 150 | es |
dc.identifier.publicationlastpage | 162 | es |
dc.identifier.publicationtitle | ELECTRIC POWER SYSTEMS RESEARCH | es |
dc.identifier.publicationvolume | 167 | es |
dc.identifier.uri | https://hdl.handle.net/10016/37860 | |
dc.identifier.uxxi | AR/0000022865 | |
dc.language.iso | eng | es |
dc.publisher | Elsevier | es |
dc.rights | © The author(s) | es |
dc.rights | Atribución 3.0 España | * |
dc.rights.accessRights | open access | es |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/es/ | * |
dc.subject.other | Condition monitoring | en |
dc.subject.other | Rogowski coil | en |
dc.subject.other | Dielectric insulation | en |
dc.subject.other | Partial discharge | en |
dc.subject.other | Medium voltage cable | en |
dc.subject.other | Transformer | en |
dc.title | Online condition monitoring of MV cable feeders using Rogowski coil sensors for PD measurements | en |
dc.type | research article | * |
dc.type.hasVersion | VoR | * |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1