A Wideband Bear-Shaped Compact Size Implantable Antenna for In-Body Communications
Editorial:
MDPI AG
Fecha de edición:
2022-03-10
Cita:
Ahmad, S., Manzoor, B., Paracha, K. N., Haider, S., Liaqat, M., Al-Gburi, A. J. A., Ghaffar, A., Alibakhshikenari, M., & Dalarsson, M. (2022). A Wideband Bear-Shaped Compact Size Implantable Antenna for In-Body Communications. In Applied Sciences (Vol. 12, Issue 6, p. 2859). MDPI AG.
ISSN:
2076-3417
Patrocinador:
European Commission
Universidad Carlos III de Madrid
Agradecimientos:
This project received funding from Universidad Carlos III de Madrid and the European
Union’s Horizon 2020 research and innovation program, under the Marie Sklodowska-Curie Grant
801538. It also received partial funding from the Researchers Supporting Project number (RSP-
2021/399), King Saud University, Riyadh, Saudi Arabia.
Proyecto:
info:eu-repo/grantAgreement/EC/H2020/COFUND-GA-2017-801538
Palabras clave:
Implantable antenna
,
Bear-shaped patch
,
Wideband performance
,
Compact size
,
Biomedical
,
Applications
Derechos:
© 2022 by the authors.
Licensee MDPI, Basel, Switzerland.
Atribución 3.0 España
Resumen:
Biomedical implantable antennas play a vital role in medical telemetry applications. These types of biomedical implantable devices are very helpful in improving and monitoring patients' living situations on a daily basis. In the present paper, a miniaturized f
Biomedical implantable antennas play a vital role in medical telemetry applications. These types of biomedical implantable devices are very helpful in improving and monitoring patients' living situations on a daily basis. In the present paper, a miniaturized footprint, thin-profile bear-shaped in-body antenna operational at 915 MHz in the industrial, scientific, and medical (ISM) band is proposed. The design is a straightforward bear-shaped truncated patch excited by a 50-W coaxial probe. The radiator is made up of two circular slots and one rectangular slot at the feet of the patch, and the ground plane is sotted to achieve a broadsided directional radiation pattern, imprinted on a Duroid RT5880 roger substrate with a typical 0.254-mm thickness ( er = 2.2, tan d = 0.0009). The stated antenna has a complete size of 7 mm x 7 mm x 0.254 mm and, in terms of guided wavelength, of 0.027lg x 0.027lg x 0.0011lg. When operating inside skin tissues, the antenna covers a measured bandwidth from 0.86 GHz to 1.08 GHz (220 MHz). The simulations and experimental outcomes of the stated design are in proper contract. The obtained results show that the calculated specific absorption rate (SAR) values inside skin of over 1 g of mass tissue is 8.22 W/kg. The stated SAR values are lower than the limitations of the federal communications commission (FCC). Thus, the proposed miniaturized antenna is an ultimate applicant for in-body communications.
[+]
[-]
Mostrar el registro completo del ítem
Impacto: