Kinetic study of epoxy curing in the glass fiber/epoxy interface using dansyl fluorescence

e-Archivo Repository

Show simple item record

dc.contributor.author Olmos Díaz, Dania
dc.contributor.author Aznar Jiménez, Antonio
dc.contributor.author Baselga Llidó, Juan
dc.contributor.author González Benito, Francisco Javier
dc.date.accessioned 2017-11-21T10:19:24Z
dc.date.available 2017-11-21T10:19:24Z
dc.date.issued 2003-10-10
dc.identifier.bibliographicCitation Olmos, D., Aznar, A. J., Baselga, J. & González-Benito, J. (2003). Kinetic study of epoxy curing in the glass fiber/epoxy interface using dansyl fluorescence. Journal of Colloid and Interface Science, 267 (1), pp. 117-126.
dc.identifier.issn 0021-9797
dc.identifier.uri http://hdl.handle.net/10016/25913
dc.description.abstract The fluorescence response of the dansyl chromophore has been used to study the kinetic of epoxy curing processes. With this new method, comparison between the curing at the interface of a glass fiber/epoxy and in the epoxy bulk of a composite material was studied. The effect of two glass fiber surface treatments was investigated. Commercial E-glass fibers were surface coated with 3-aminopropyltriethoxysilane (APTES) and 3-aminopropylmethyldiethoxysilane (APDES). Fluorimetry (using fluorescent labels) and FT-NIR (Fourier transformed infrared spectroscopy in the near range) techniques were used to monitor the curing process in these composite materials. From the analysis of the data obtained, different simple kinetic models were discussed and apparent activation energies were obtained. Furthermore, from those techniques the respective results were compared to obtain complementary information. Independently of the sample and the technique used for the kinetic analysis, no variation of the activation energy of the epoxy curing reaction was found, which suggests that there are no changes in the mechanism of the reaction along the process. Fluorescence from dansyl located at the glass fiber/epoxy interface reflected that the kind of reinforcement treatment clearly affects the epoxy curing process exactly in that region. However, when analytical response comes from the whole system the mechanism of the reaction does not seem to change with the silane coating used although is quite different in comparison with the process at the interface.
dc.description.sponsorship The authors gratefully acknowledge the Contrato- Programa del III PRICIT de la CAM and the FIBRODONT (MAT2001-0677-P3) project for financial support.
dc.format.extent 10
dc.format.mimetype application/pdf
dc.language.iso eng
dc.publisher Elsevier
dc.rights © Elsevier, 2003
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subject.other Fluorescence
dc.subject.other Interfaces
dc.subject.other Composites
dc.subject.other Epoxy
dc.title Kinetic study of epoxy curing in the glass fiber/epoxy interface using dansyl fluorescence
dc.type article
dc.subject.eciencia Materiales
dc.subject.eciencia Química
dc.identifier.doi https://doi.org/10.1016/S0021-9797(03)00620-9
dc.rights.accessRights openAccess
dc.relation.projectID Comunidad de Madrid. MAT2001-0677-P3
dc.type.version acceptedVersion
dc.identifier.publicationfirstpage 117
dc.identifier.publicationissue 1
dc.identifier.publicationlastpage 126
dc.identifier.publicationtitle Journal of Colloid and Interface Science
dc.identifier.publicationvolume 267
dc.identifier.uxxi AR/0000004114
dc.affiliation.dpto UC3M. Departamento de Ciencia e Ingeniería de Materiales e Ingeniería Química
dc.affiliation.grupoinv UC3M. Grupo de Investigación: Polímeros y Composites
 Find Full text

Files in this item

*Click on file's image for preview. (Embargoed files's preview is not supported)


The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record