Advances in navigation and intraoperative imaging for intraoperative electron radiotherapy

e-Archivo Repository

Show simple item record

dc.contributor.advisor Pascau González-Garzón, Javier
dc.contributor.author García Vázquez, Verónica
dc.date.accessioned 2017-06-21T13:01:46Z
dc.date.available 2017-06-21T13:01:46Z
dc.date.issued 2017-01
dc.date.submitted 2017-01-20
dc.identifier.uri http://hdl.handle.net/10016/24703
dc.description Mención Internacional en el título de doctor
dc.description.abstract Esta tesis se enmarca dentro del campo de la radioterapia y trata específicamente sobre la radioterapia intraoperatoria (RIO) con electrones. Esta técnica combina la resección quirúrgica de un tumor y la radiación terapéutica directamente aplicada sobre el lecho tumoral post-resección o sobre el tumor no resecado. El haz de electrones de alta energía es colimado y conducido por un aplicador específico acoplado a un acelerador lineal. La planificación de la RIO con electrones es compleja debido a las modificaciones geométricas y anatómicas producidas por la retracción de estructuras y la eliminación de tejidos cancerosos durante la cirugía. Actualmente, no se dispone del escenario real en este tipo de tratamientos (por ejemplo, la posición/orientación del aplicador respecto a la anatomía del paciente o las irregularidades en la superficie irradiada), sólo de una estimación grosso modo del tratamiento real administrado al paciente. Las imágenes intraoperatorias del escenario real durante el tratamiento (concretamente imágenes de tomografía axial computarizada [TAC]) serían útiles no sólo para la planificación intraoperatoria, sino también para registrar y evaluar el tratamiento administrado al paciente. Esta información es esencial en estudios prospectivos. En esta tesis se evaluó en primer lugar la viabilidad de un sistema de seguimiento óptico de varias cámaras para obtener la posición/orientación del aplicador en los escenarios de RIO con electrones. Los resultados mostraron un error de posición del aplicador inferior a 2 mm (error medio del centro del bisel) y un error de orientación menor de 2º (error medio del eje del bisel y del eje longitudinal del aplicador). Estos valores están dentro del rango propuesto por el Grupo de Trabajo 147 (encargo del Comité de Terapia y del Subcomité para la Mejora de la Garantía de Calidad y Resultados de la Asociación Americana de Físicos en Medicina [AAPM] para estudiar en radioterapia externa la exactitud de la localización con métodos no radiográficos, como los sistemas infrarrojos). Una limitación importante de la solución propuesta es que el aplicador se superpone a la imagen preoperatoria del paciente. Una imagen intraoperatoria proporcionaría información anatómica actualizada y permitiría estimar la distribución tridimensional de la dosis. El segundo estudio específico de esta tesis evaluó la viabilidad de adquirir con un TAC simulador imágenes TAC intraoperatorias de escenarios reales de RIO con electrones. No hubo complicaciones en la fase de transporte del paciente utilizando la camilla y su acople para el transporte, o con la adquisición de imágenes TAC intraoperatorias en la sala del TAC simulador. Los estudios intraoperatorios adquiridos se utilizaron para evaluar la mejora obtenida en la estimación de la distribución de dosis en comparación con la obtenida a partir de imágenes TAC preoperatorias, identificando el factor dominante en esas estimaciones (la región de aire y las irregularidades en la superficie, no las heterogeneidades de los tejidos). Por último, el tercer estudio específico se centró en la evaluación de varias tecnologías TAC de kilovoltaje, aparte del TAC simulador, para adquirir imágenes intraoperatorias con las que estimar la distribución de la dosis en RIO con electrones. Estos dispositivos serían necesarios en el caso de disponer de aceleradores lineales portátiles en el quirófano ya que no se aprobaría mover al paciente a la sala del TAC simulador. Los resultados con un maniquí abdominal mostraron que un TAC portátil (BodyTom) e incluso un acelerador lineal con un TAC de haz de cónico (TrueBeam) serían adecuados para este propósito.
dc.description.abstract This thesis is framed within the field of radiotherapy, specifically intraoperative electron radiotherapy (IOERT). This technique combines surgical resection of a tumour and therapeutic radiation directly applied to a post-resection tumour bed or to an unresected tumour. The high-energy electron beam is collimated and conducted by a specific applicator docked to a linear accelerator (LINAC). Dosimetry planning for IOERT is challenging owing to the geometrical and anatomical modifications produced by the retraction of structures and removal of cancerous tissues during the surgery. No data of the actual IOERT 3D scenario is available (for example, the applicator pose in relation to the patient’s anatomy or the irregularities in the irradiated surface) and consequently only a rough approximation of the actual IOERT treatment administered to the patient can be estimated. Intraoperative computed tomography (CT) images of the actual scenario during the treatment would be useful not only for intraoperative planning but also for registering and evaluating the treatment administered to the patient. This information is essential for prospective trials. In this thesis, the feasibility of using a multi-camera optical tracking system to obtain the applicator pose in IOERT scenarios was firstly assessed. Results showed that the accuracy of the applicator pose was below 2 mm in position (mean error of the bevel centre) and 2º in orientation (mean error of the bevel axis and the longitudinal axis), which are within the acceptable range proposed in the recommendation of Task Group 147 (commissioned by the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine [AAPM] to study the localization accuracy with non-radiographic methods such as infrared systems in external beam radiation therapy). An important limitation of this solution is that the actual pose of applicator is superimposed on a patient’s preoperative image. An intraoperative image would provide updated anatomical information and would allow estimating the 3D dose distribution. The second specific study of this thesis evaluated the feasibility of acquiring intraoperative CT images with a CT simulator in real IOERT scenarios. There were no complications in the whole procedure related to the transport step using the subtable and its stretcher or the acquisition of intraoperative CT images in the CT simulator room. The acquired intraoperative studies were used to evaluate the improvement achieved in the dose distribution estimation when compared to that obtained from preoperative CT images, identifying the dominant factor in those estimations (air gap and the surface irregularities, not tissue heterogeneities). Finally, the last specific study focused on assessing several kilovoltage (kV) CT technologies other than CT simulators to acquire intraoperative images for estimating IOERT dose distribution. That would be necessary when a mobile electron LINAC was available in the operating room as transferring the patient to the CT simulator room could not be approved. Our results with an abdominal phantom revealed that a portable CT (BodyTom) and even a LINAC with on-board kV cone-beam CT (TrueBeam) would be suitable for this purpose.
dc.format.mimetype application/pdf
dc.language.iso eng
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subject.other Proceso de imágenes
dc.subject.other Optoelectrónica
dc.subject.other Terapéutica
dc.subject.other Cáncer
dc.subject.other Ingeniería biomédica
dc.subject.other Intraoperative electron radiation therapy
dc.subject.other IOERT
dc.subject.other Radioterapia intraoperatoria
dc.subject.other RIO
dc.title Advances in navigation and intraoperative imaging for intraoperative electron radiotherapy
dc.type doctoralThesis
dc.subject.eciencia Biología y Biomedicina
dc.subject.eciencia Medicina
dc.rights.accessRights openAccess
dc.description.degree Programa Oficial de Doctorado en Multimedia y Comunicaciones
dc.description.responsability Presidente: Joaquín López Herráiz.- Secretario: María Arrate Muñoz Barrutia.- Vocal: Óscar Acosta Tamayo
dc.contributor.departamento Universidad Carlos III de Madrid. Departamento de Bioingeniería e Ingeniería Aeroespacial
 Find Full text

Files in this item

*Click on file's image for preview. (Embargoed files's preview is not supported)


The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record