dc.contributor.author |
Herraiz, J. L. |
dc.contributor.author |
España, Samuel |
dc.contributor.author |
Vicente, Esther |
dc.contributor.author |
Vaquero López, Juan José
|
dc.contributor.author |
Desco Menéndez, Manuel
|
dc.contributor.author |
Udías, José Manuel |
dc.date.accessioned |
2011-10-06T09:29:13Z |
dc.date.available |
2011-10-06T09:29:13Z |
dc.date.issued |
2007 |
dc.identifier.bibliographicCitation |
Published in: 2006 IEEE Nuclear Science Symposium Conference Record, 2006, vol. 6, p. 3404 - 3407 |
dc.identifier.isbn |
1-4244-0560-2 |
dc.identifier.issn |
1082-3654 |
dc.identifier.uri |
http://hdl.handle.net/10016/12238 |
dc.description |
Proceeding of: 2006 IEEE Nuclear Science Symposium Conference Record, San Diego, CA, Oct. 29 - Nov. 1, 2006 |
dc.description.abstract |
We present an optimal and robust technique for the restoration of positron emission tomography (PET) data. It is based on an iterative deconvolution of Fourier Rebinned (FORE) sinograms employing the EM-ML algorithm regularized with MAP. The deconvolution kernel is related to the System Response Matrix (SRM) and the axial point spread function(PSF) caused by FORE. This method is able to deblur the acquired data whitout the introduction of additional noise and enhancing the quality (resolution, contrast) of the images reconstructed using FBP. |
dc.description.sponsorship |
Support from UCM grant. J.M. Udias acknowledges support from MEC (FPA2006-
07393) and CENIT (Ministerio de Industria, Spain). Part of the computations of this work were done at the “High capacity
cluster for physical techniques” of the Faculty for Physical Sciences of UCM, funded in part by the UE under the FEDER
program and in part by the UCM. |
dc.format.mimetype |
application/pdf |
dc.language.iso |
eng |
dc.publisher |
IEEE |
dc.rights |
© IEEE |
dc.subject.other |
Positron Emission Tomography (PET) |
dc.subject.other |
Sinogram Restoration |
dc.subject.other |
Image reconstruction |
dc.subject.other |
Resolution |
dc.subject.other |
Noise |
dc.title |
Optimal and robust PET data sinogram restoration based on the response of the system |
dc.type |
bookPart |
dc.type |
conferenceObject |
dc.relation.publisherversion |
http://dx.doi.org/10.1109/NSSMIC.2006.353732 |
dc.subject.eciencia |
Biología y Biomedicina |
dc.identifier.doi |
10.1109/NSSMIC.2006.353732 |
dc.rights.accessRights |
openAccess |
dc.relation.eventdate |
Oct. 29 - Nov. 1, 2006 |
dc.relation.eventplace |
San Diego, CA |
dc.relation.eventtitle |
2006 IEEE Nuclear Science Symposium Conference Record |
dc.identifier.publicationfirstpage |
3404 |
dc.identifier.publicationlastpage |
3407 |
dc.identifier.publicationtitle |
2006 IEEE Nuclear Science Symposium Conference Record |
dc.identifier.publicationvolume |
6 |