Español English Contacte con nosotros http://www.uc3m.es/portal/page/portal/biblioteca
DSpace e-Archivo

Archivo Abierto Institucional de la Universidad Carlos III de Madrid > Investigación > Departamentos > Departamento de Bioingeniería e Ingeniería Aeroespacial: Bioingeniería > DBIAB - Journal Articles >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10016/9367

Files in This Item:
vaquero_resolution_MRI_2004_ps.pdf629,33 kBAdobe PDFformato pdf
Title: Resolution recovery in Turbo Spin Echo using segmented Half Fourier acquisition
Author(s): Santa-Marta, Cristina
Lafuente, Javier
Vaquero, Juan José
García-Barreno, Pedro
Desco, Manuel
Publisher: Elsevier
Issued date: Apr-2004
Citation: Magnetic Resonance Imaging, 2004, vol. 22, n. 3, p. 369-378
URI: http://hdl.handle.net/10016/9367
ISSN: 0730-725X
DOI: http://dx.doi.org/10.1016/j.mri.2004.01.009
Abstract: Turbo Spin Echo (TSE) is a sequence of choice for obtaining T2-weighted images. TSE reduces acquisition time by acquiring several echoes within each TR, at the cost of introducing an exponential weighting in the k-space that leads to a certain image blurring. This is particularly important for short-T2 structures, which can even disappear if their size in the phase encoding direction is comparable to the degree of blurring. This article suggests the use of a combination of Half Fourier (HF) and segmented (multishot) TSE (sHF-TSE) to recover the original resolution of the SE images. The improved symmetry of the dataset achieved by HF reconstruction is used to increase the resolution of the TSE images. The proposed combination, available in most clinical scanners, reduces the blurring artifact inherent to the TSE sequence without increasing the scan time or the number of acquisitions, but at the cost of a slight reduction of the signal-to-noise ratios (SNR). Qualitative and quantitative results are presented using both numerical simulation and imaging. Significant edge enhancement has been achieved for structures with short T2, (narrowing of the full width at half maximum [FWHM] up to 45%). The proposed sequence is more sensitive to movement artifacts but has proven to be superior to the conventional TSE for imaging static structures
Review: PeerReviewed
Publisher version: http://dx.doi.org/10.1016/j.mri.2004.01.009
Keywords: TSE
FSE
Resolution
SNR
k-Space
Rights: © Elsevier
Appears in Collections:DBIAB - Journal Articles

Refworks Export

SFX Query

Items in E-Archivo are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! © Universidad Carlos III de Madrid - Software DSpace - Terms of use - Feedback