Title: Performance evaluation of a new gamma imager for small animal SPECT applications
Author(s): Lage, Eduardo
Vaquero, Juan José
Villena, José L.
Carlos, Álvaro de
Tapias, Gustavo
Sisniega, Alejandro
Desco, Manuel
Publisher: IEEE
Issued date: 2007
Citation: 2007 IEEE Nuclear Science Symposium Conference Record, 2007, vol. 5, p. 3355 - 3360
URI: http://hdl.handle.net/10016/12230
ISBN: 978-1-4244-0922-8
ISSN: 1082-3654
DOI: http://dx.doi.org/10.1109/NSSMIC.2007.4436851
Description: Proceeding of: 2007 IEEE Nuclear Science Symposium Conference Record (NSS '07), Honolulu, Hawaii, USA, Oct. 27 - Nov. 3, 2007
Abstract: Abstract–In this work we characterized a recently developed gamma imager for small animal SPECT applications. The Hamamatsu C9177 is a mini-gamma camera that integrates the detector and all the electronics, including the acquisition system, in a compact and portable housing. The detector is based on a high resolution parallel hole collimator, a CsI(NaI) crystal array and a PS-PMT (flat panel type). The active field of view is 41.9 x 41.9 mm2 and the assembly is optimized for 60 to 200 keV. The electronics in the housing includes the high voltage divider, an ASIC which converts the 64 anodes into Anger-like signals, ADCs which are fed with these signals and position and energy lookup tables which allow digital information for each detected photon to be obtained directly from the imager. In order to be able to obtain tomographic data and to improve the measurement protocols, we mounted the detector in a custom-built motorized gantry. We evaluated detector uniformity and energy resolution using a flood field image. Planar intrinsic spatial resolution and spatial linearity were assessed by stepping a capillary source across the detector surface and plotting the count profile for each individual crystal of the array. We additionally performed phantom studies to preliminarily characterize the tomographic performance. Energy resolution is 11.6% (mean), sensitivity is 2.54 cps/μCi and planar spatial resolution is 2.4 mm (CFOV 20% energy window) when the source is placed on the detector surface.
Sponsor: This work was supported in part by the Spanish Ministerio de Educación y Ciencia under Grant No. TEC2004-07052-C02, Comunidad de Madrid Grant No. GR/SAL/024104, and the CDTEAM project of the CENIT program (Spanish Ministerio de Industria).
Publisher version: http://dx.doi.org/10.1109/NSSMIC.2007.4436851
Rights: © IEEE
Appears in Collections:DBIAB - Proceedings
DBIAB - Book Chapters

Refworks Export

SFX Query

Items in E-Archivo are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! © Universidad Carlos III de Madrid - Software DSpace - Terms of use - Feedback