Title: Automated method for small-animal PET image registration with intrinsic validation
Author(s): Pascau, Javier
Gispert, Juan Domingo
Michaelides, Michael
Thanos, Panayotis K.
Volkow, Nora D.
Vaquero, Juan José
Soto-Montenegro, María Luisa
Desco, Manuel
Publisher: Springer
Issued date: 2009
Citation: Molecular Imaging and Biology, 2009, vol. 11, n. 2, p. 107-113
URI: http://hdl.handle.net/10016/12023
ISSN: 1536-1632 (print version)
1860-2002 (electronic version)
DOI: http://dx.doi.org/10.1007/s11307-008-0166-z
Abstract: We propose and compare different registration approaches to align small-animal PET studies and a procedure to validate the results by means of objective registration consistency measurements. Procedures: We have applied a registration algorithm based on information theory, using different approaches to mask the reference image. The registration consistency allows for the detection of incorrect registrations. This methodology has been evaluated on a test dataset(FDG-PET rat brain images). Results: The results show that a multiresolution two-step registration approach based on the use of the whole image at the low resolution step, while masking the brain at the high resolution step, provides the best robustness (87.5% registration success) and highest accuracy (0.67-mm average). Conclusions: The major advantages of our approach are minimal user interaction and automatic assessment of the registration error, avoiding visual inspection of the results, thus facilitating the accurate, objective, and rapid analysis of large groups of rodent PET images
Sponsor: This work was supported by projects CIBER CB06/01/0079 (Ministerio de Sanidad y Consumo) and CDTEAM (CENIT program, Ministerio de Industria). Further support came from NIAAA Intramural Research Program (AA 11034 and AA07574, AA07611) and the US Department of Energy (DE-AC02-98CH10886)
Publisher version: http://dx.doi.org/10.1007/s11307-008-0166-z
Keywords: Image registration
Positron emission tomography (PET)
Validation
Algorithm
Rats
Rights: ©Springer
Appears in Collections:DBIAB - Journal Articles

Refworks Export

SFX Query

Items in E-Archivo are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! © Universidad Carlos III de Madrid - Software DSpace - Terms of use - Feedback