| Title: | Iterative 4D reconstruction of dynamic SPECT images |
| Author(s): | Abella, Mónica Reutter, B. W. Vaquero, Juan José Desco, Manuel Gullberg, G. T. |
| Publisher: | Springer |
| Issued date: | Jun-2008 |
| Citation: | International Journal of Computer Assisted Radiology and Surgery, Jun. 2008, vol. 3, supplement 1, p. S358-S360 |
| URI: | http://hdl.handle.net/10016/12019 |
| ISSN: | 1861-6410 (print version) 1861-6429 (electronic version) |
| DOI: | http://dx.doi.org/10.1007/s11548-008-0206-9 |
| Description: | [Abstract] The 22nd International Congress and Exhibition, Barcelona, Spain, June 25-28, 2008 |
| Abstract: | The present work presents a new approach for the 4D reconstruction algorithm for dynamic SPECT in a parallel ray geometry based on B-splines including attenuation map from CT and geometry efficiency correction. In this work we make use of 4 piecewise piecewise quadratic temporal splines and a reconstruction algorithm based on the iterative maximization of Poisson likelihood. Results on a Tecnetium (99mTc-Teboroxime) canine study are shown |
| Publisher version: | http://dx.doi.org/10.1007/s11548-008-0206-9 |
| Keywords: | Dynamic SPECT Reconstruction 4D |
| Rights: | © Springer |