Publication: Preliminary studies on the design and simulation of high resolution small animal PET scanners with octagonal geometry
dc.affiliation.dpto | UC3M. Departamento de Bioingeniería | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: Biomedical Imaging and Instrumentation Group | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: BSEL - Laboratorio de Ciencia e Ingeniería Biomédica | es |
dc.contributor.author | Ortuño, Juan E. | |
dc.contributor.author | Vaquero López, Juan José | |
dc.contributor.author | Kontaxakis, George | |
dc.contributor.author | Desco Menéndez, Manuel | |
dc.contributor.author | Santos, Andrés | |
dc.date.accessioned | 2012-06-15T10:37:11Z | |
dc.date.available | 2012-06-15T10:37:11Z | |
dc.date.issued | 2003 | |
dc.description | Proceding of: 2003 IEEE Nuclear Science Symposium Conference Record, Portland, Oregon, USA, 19-25 October, 2003 | |
dc.description.abstract | We present a preliminary study on the design of a small animal positron emission tomograph with octagonal geometry. The main goal is to evaluate the impact of critical design parameters on the quality of the reconstructed images. Monte Carlo simulations take into account the depth of interaction in individual crystals. The activity sources are simulated as parametric distributions within the field of view and images are reconstructed with iterative algorithms based on the estimation of maximum likelihood and Bayesian regularization. The probability system matrix used by these algorithms is also calculated based on statistical models and Monte Carlo simulation. 2D and 3D techniques have been employed. | |
dc.description.sponsorship | This work has been partly founded by the Spanish Ministry of Science & Technology, (TIC 2001-0175-C03) and by Red Temática IM3 from Spanish Health Ministry (G03/185). | |
dc.description.status | Publicado | |
dc.format.mimetype | application/pdf | |
dc.identifier.bibliographicCitation | 2003 IEEE Nuclear Science Symposium Conference Record, 2003, vol. 3, pp. 2053 - 2057 | |
dc.identifier.doi | 10.1109/NSSMIC.2003.1352284 | |
dc.identifier.isbn | 0-7803-8257-9 | |
dc.identifier.issn | 1082-3654 | |
dc.identifier.publicationfirstpage | 2053 | |
dc.identifier.publicationlastpage | 2057 | |
dc.identifier.publicationtitle | 2003 IEEE Nuclear Science Symposium Conference Record | |
dc.identifier.publicationvolume | vol. 3 | |
dc.identifier.uri | https://hdl.handle.net/10016/14590 | |
dc.language.iso | eng | |
dc.publisher | IEEE | |
dc.relation.eventdate | 19-25 October, 2003 | |
dc.relation.eventplace | Portland, Oregon, USA | |
dc.relation.eventtitle | 2003 IEEE Nuclear Science Symposium Conference Record | |
dc.relation.publisherversion | http://dx.doi.org/10.1109/NSSMIC.2003.1352284 | |
dc.rights | © IEEE | |
dc.rights.accessRights | open access | |
dc.subject.eciencia | Biología y Biomedicina | |
dc.title | Preliminary studies on the design and simulation of high resolution small animal PET scanners with octagonal geometry | |
dc.type | conference proceedings | * |
dc.type.hasVersion | AM | * |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- preliminary_IEEE_2003_ps.pdf
- Size:
- 522.74 KB
- Format:
- Adobe Portable Document Format