Publication: Effects of the super bialkali photocathode on the performance characteristics of a position-sensitive depth-of-interaction PET detector module
dc.affiliation.dpto | UC3M. Departamento de Bioingeniería | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: Biomedical Imaging and Instrumentation Group | es |
dc.affiliation.grupoinv | UC3M. Grupo de Investigación: BSEL - Laboratorio de Ciencia e Ingeniería Biomédica | es |
dc.contributor.author | Vaquero López, Juan José | |
dc.contributor.author | Udías, José Manuel | |
dc.contributor.author | Desco Menéndez, Manuel | |
dc.date.accessioned | 2011-09-16T11:45:34Z | |
dc.date.available | 2011-09-16T11:45:34Z | |
dc.date.issued | 2009 | |
dc.description | Proceeding of: IEEE Nuclear Science Symposium Conference. NNS 2008, Dresden, Germany, Oct. 19-25, 2008 | |
dc.description.abstract | Super Bialkali (SBA) and Ultra Bialkali (UBA) photocathodes are new technologies that improve the spectral response characteristics of position sensitive PMTs, boosting their quantum efficiency up to 35% and 43% (typ.) respectively [ref Hamamatsu]. Two SBA tubes were introduced into a production line of PET detectors mixed with the regular ones. The detectors were assembled on the same day and by the same operator using the standard factory protocols for detector mounting, calibration and testing. In this work we are reporting our evaluation of the achieved improvement by comparing the spatial and energy resolutions and the depth of-interaction performance of a PET detector modules with DOI capabilities assembled using the regular and the SBA versions of the same PS-PMT. We conclude that the superior performance of the SBA tube may enable the use of arrays with a larger number of crystals of smaller footprint, thus improving the detector intrinsic spatial resolution without degrading the energy resolution or the phoswich discrimination capability | |
dc.description.sponsorship | This work was supported in part by the CENIT Programme (Ministerio de Industria), CIBER CB07/09/0031, RETIC-RECAVA (Ministerio de Sanidad y Consumo), and TEC2007-64731/TCM (Ministerio de Educación y Ciencia) | |
dc.format.mimetype | application/pdf | |
dc.identifier.bibliographicCitation | Nuclear Science Symposium Conference Record, 2009, p. 4945-4947 | |
dc.identifier.doi | 10.1109/NSSMIC.2008.4774349 | |
dc.identifier.isbn | 978-1-4244-2714-7 | |
dc.identifier.issn | 1082-3654 | |
dc.identifier.publicationfirstpage | 4945 | |
dc.identifier.publicationlastpage | 4947 | |
dc.identifier.publicationtitle | Nuclear Science Symposium Conference Record | |
dc.identifier.uri | https://hdl.handle.net/10016/12102 | |
dc.language.iso | eng | |
dc.publisher | IEEE | |
dc.relation.eventdate | October 19 - 25, 2008 | |
dc.relation.eventplace | Dresden, Germany | |
dc.relation.eventtitle | IEEE Nuclear Science Symposium Conference. NNS 2008 | |
dc.relation.publisherversion | http://dx.doi.org/10.1109/NSSMIC.2008.4774349 | |
dc.rights | © IEEE | |
dc.rights.accessRights | open access | |
dc.subject.eciencia | Biología y Biomedicina | |
dc.title | Effects of the super bialkali photocathode on the performance characteristics of a position-sensitive depth-of-interaction PET detector module | |
dc.type | conference paper | * |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- bialkali_IEEE_2008_ps.pdf
- Size:
- 563.23 KB
- Format:
- Adobe Portable Document Format